An independent check for PLC code, before it reaches the machine.
A PLC compiler tells you that the code builds. It does not tell you what the machine will do when a sensor is late or a valve is slow. Eyetory is a checker we are building for IEC 61131-3 Structured Text: you will save an ST file, and it will read the code with the machine’s I/O list and answer green, amber or red, naming the possible hazard and the actuator timing under which it appears. It is meant to check code, not write it.
01 / Illustration
Illustration: code and finding
PROGRAM TransferVARStep : INT := 0;StartReq : BOOL; (* part at infeed *)PartAtEnd : BOOL; (* outfeed sensor *)Conveyor : BOOL; (* belt motor *)tTransfer : TON;END_VARtTransfer(IN := (Step = 10), PT := T#4S);CASE Step OF0: Conveyor := FALSE;IF StartReq THENStep := 10;END_IF;10: Conveyor := TRUE;IF tTransfer.Q THENAmberStep := 20;END_IF;20: Conveyor := FALSE;Step := 0;END_CASE;END_PROGRAM
Finding on line 18
- Verdict
- Amber
- Hazard class
- Step advanced by a timer without sensor confirmation.
- Line 18
- Step 10 moves to step 20 when
tTransferreaches 4 s, whether or not the part has arrived. - Timing
- Appears when the transfer takes longer than
T#4S, for example a slipping belt or a heavy part: the belt stops with the part short of the outfeed, and the sequence carries on as if it had arrived. - I/O list
PartAtEndis listed as the outfeed sensor and is never read.
02 / What it checks
Six questions about timing and state
The questions Eyetory is being designed to ask of each program, in plain words:
Two commands in conflict in the same scan
Two parts of the program drive one actuator, or two opposed actuators, against each other within a single scan cycle.
A step advanced by a timer alone
A sequence step moves on when a timer expires, without a sensor confirming that the movement actually finished.
An interlock that drops with its sensor
An interlock is bypassed when the sensor it depends on drops out, so the guarded output can switch without it.
State lost after an E-stop reset
After an emergency-stop reset, a sequence restarts from the wrong step or with outputs it should not have.
A timer called twice per scan
One TON or TOF instance is called twice in a scan, so its elapsed time and output stop meaning what the code assumes.
Two sequences waiting on each other
Two sequences each hold a shared resource the other needs, such as a transfer table or a pump, and neither can move.
03 / Why independent
Separate from the tools that wrote the code
- Any source
- Planned to read Structured Text from any vendor’s tools and from any AI assistant. AI assistants now write PLC code too.
- Offline
- Planned to run on the engineer’s own PC, so the code does not have to leave it.
- Timing
- A compiler checks that code builds. Eyetory is meant to ask what happens while actuators take their time: a late sensor, a slow valve, a belt that slips.
04 / Status
Early, and nothing measured yet
Eyetory is in development. We have no results of our own to show, so this page shows none. The first step is our own measurement on PLCWorld, a public benchmark for PLC programming published by its authors. PLCWorld is cited as a planned benchmark, not as endorsement of Eyetory.
We will publish the results here when they exist, including the cases where other approaches do better.
05 / Early access
Early access
Want details about Eyetory? Leave your email to request a personal reply. This does not add you to a mailing list.